Job Title
- NICET III Fire Sprinkler Designer
- Location :
- [Jefferson City, MO] [Onsite / Remote with periodic site travel]
- Department :
- Fire Protection / Life Safety
- Reports To :
- [Design Manager / Project Manager]
- Employment Type :
- [Full-time]
About the Role
Were hiring a NICET IIIcertified sprinkler designer to take ownership of code-compliant water-based fire protection designs from survey through as-builts. Youll coordinate with project management, fabrication, field crews, and AHJs to produce accurate layouts, perform hydraulic calculations, and deliver permit and installation packages on time and on budget.
What Youll Do
Design & DraftingDevelop code-compliant sprinkler system layouts (wet, dry, pre-action, as applicable) in AutoCAD / Revit with detailed plans, section views, riser details, hangers / seismic bracing, and valve schedules.Prepare completeshop / permit drawings, submittals, and as-builts; coordinate PE seals where required.Hydraulic Calculations & Engineering SupportPerform and document hydraulic calculations; size mains / branches; analyze water supplies and fire pump / standpipe demands.Specify components to applicable listings / approvals (UL / FM) and project standards.Codes, Standards & ComplianceApply NFPA 13 / 14 / 20 and relevant I-Codes; incorporate jurisdictional amendments and owner insurance requirements (e.g., FM Global).Lead coordination with AHJsrespond to review comments and manage revisions to approval.BIM & CoordinationParticipate in BIM coordination and clash detection with MEP / structural trades; issue RFIs, track changes, and maintain the model.Field & Fabrication InterfaceConduct site surveys and field verifications; generate material lists, spools, and fabrication packets; support field installation and commissioning.Project ExecutionMaintain drawing logs, revision control, and design schedules; forecast design hours, support change orders, and contribute to project closeout.Required Qualifications
NICET Level IIIin Water-Based Systems Layout (active and in good standing).5+ yearsof sprinkler design experience delivering commercial / industrial / healthcare or storage projects.Proficiency inAutoCAD(advanced) and working knowledge ofRevitor willingness to upskill quickly.Hands-on experience withhydraulic calc tools(e.g., HydraCALC / HydraCAD, AutoSPRINK, HASS, or SprinkCAD) andBluebeam Revufor markups.Strong command ofNFPA 13 / 14 / 20, IBC / IFC basics, and submittal / permit processes; familiarity with local amendments.Ability to read architectural / structural drawings, coordinate penetrations / supports, and detailseismic bracingClear, professional communication with PMs, field teams, clients, and AHJs; strong documentation habits.Valid drivers license and ability to conductsite visits, including occasional ladder / lift access with proper PPE.Nice-to-Have
Experience withstorage occupancies(ESFR, CMSA, high-piled storage) andpump / standpipesystems.Navisworks Managefor clash detection;BIM 360 / Autodesk Construction Cloudworkflows.Exposure toFM Global Data Sheetsand insurance-driven criteria.Basic pump selection / sizing and acceptance testing support.NICET IV or path toward IV; OSHA-10 / 30.Tools Youll Use
CAD / BIM :AutoCAD, Revit, NavisworksCalcs / Design Suites :HydraCAD / HydraCALC, SprinkCAD, AutoSPRINK, HASSCollaboration :Bluebeam Revu, BIM 360 / ACC, Microsoft 365Key Results (How Well Measure Success)
First 3060 days :Produce permit-ready drawings for at least [3-4] active projects with minimal rework; close out [75]% of AHJ comments on first review.By 6 months :Maintainon-time submittals 95%, averagerework < 5%of design hours, and passAHJ first-pass approvals 80%Ongoing :Positive feedback from field on constructability; accurate and timely material lists / spool sheets.Work Environment & Physical Requirements
Office and field environments; ability to perform site surveys, take dimensions, and verify existing conditions.Lift / carry up to ~25 lbs occasionally; climb ladders; navigate active construction sites with PPE.Education & Credentials
High school diploma or equivalent required;AS / BS in engineering technologyor related field preferred.NICET III (Water-Based Systems Layout)required; continued education to maintain certification.Compensation & Benefits
Pay Range :[$90k$110k base] + [annual bonus / OT eligibility].Medical, 401(k) with match, paid time off / holidays, tuition reimbursement for NICET / CEUs, and safety gear.Flexible [hybrid / remote] policy depending on project / site needs.Equal Opportunity Statement
Korsmeyer Fire Protection is an Equal Opportunity Employer. We celebrate diversity and are committed to creating an inclusive environment for all employees.
How to Apply
Send your resume / portfolio (select plan sets and calc samples welcome) to
[ap@korsmeyerfire.com]with the subject NICET III Sprinkler Designer [Your Name].Job Type : Full-time
Projected Total Compensation : $44.00 - $53.00 per hour
Benefits :
401(k)401(k) matchingFlexible scheduleHealth insurancePaid time offProfessional development assistanceTuition reimbursementWork Location : In person
by Jobble